Measuring indoor air quality at home is most useful when readings lead to practical decisions. This guide explains how to use humidity, carbon dioxide (CO2) and PM2.5 readings, where to place a monitor, how to compare results over a week, and when ventilation or professional advice may be appropriate.
Overview
Indoor air quality changes throughout the day. Cooking, showering, drying clothes, cleaning, candles, fireplaces, traffic, pets and the number of people in a room can all affect readings. A single result is therefore less useful than a repeatable pattern recorded under normal living conditions.
Three measurements provide a practical starting point:
- Relative humidity: indicates how much moisture is in the air compared with the maximum amount the air can hold at that temperature. Persistent high humidity can increase the risk of condensation and support mould growth, particularly on cold surfaces.
- CO2: is mainly a useful indicator of occupancy and ventilation in ordinary homes. Rising indoor readings often show that stale air is not being replaced quickly enough, although CO2 does not measure every pollutant.
- PM2.5: refers to very small airborne particles. Indoor sources can include frying, frying oils, smoke, candles, dusty activities and some combustion appliances. Outdoor pollution can also enter through open windows, doors and ventilation air.
These readings should be treated as prompts for investigation rather than a medical diagnosis or a complete safety assessment. If anyone in the household has breathing difficulties, unusual symptoms or a condition affected by air quality, seek appropriate clinical advice as well as addressing the home environment.
For a broader introduction to measurements and improvements, see Indoor Air Quality at Home: What to Measure and How to Improve It.
How to estimate indoor air quality from home readings
Use the following workflow for at least several ordinary days, ideally including a weekday and a weekend. Repeat the process in different seasons because window use, heating, occupancy and outdoor conditions change.
- Choose the room. Start with the bedroom, living room and the room where condensation or odours are most noticeable. If you have one monitor, test rooms at different times rather than moving it constantly.
- Place the monitor correctly. Put it at roughly breathing height on a shelf or table, away from windows, doors, radiators, cooking appliances, extract grilles and direct sunlight. Do not place it inside a cupboard or directly beside a person.
- Allow the reading to settle. Follow the device instructions and avoid judging air quality immediately after moving the monitor. Record the room, time, temperature if available, and what was happening.
- Capture normal and high-activity periods. Record a quiet baseline, then note readings during or after showering, cooking, cleaning, drying laundry, entertaining or sleeping.
- Compare trends. Look for repeated peaks, slow recovery and differences between rooms. A reading that rises during a shower but returns after effective extraction is a different problem from humidity that stays high for hours.
A simple log can use these columns: date, time, room, humidity, CO2, PM2.5, activity, windows or fans used, and action taken. Add a short note such as “four people watching television”, “oven and hob used”, or “bathroom door left open”. Context makes the numbers useful.
Indicative ways to interpret the results
There is no single reading that describes every home. As a practical guide, a home humidity level that remains around the middle of the normal indoor range is generally easier to manage than persistently damp air. Repeatedly high readings, window condensation, musty smells or visible mould suggest that moisture sources and ventilation need attention.
For CO2, compare the reading with the outdoor baseline if your monitor provides one, and focus on duration and recovery. A sustained rise while people are present usually points to insufficient air change for that room at that time. Brief increases during gatherings are expected; readings that remain elevated overnight or return slowly after occupancy may justify checking background ventilation, trickle vents or mechanical systems.
For PM2.5, focus on sudden peaks and their likely cause. A sharp increase during frying, candle use or smoking is a source-control issue as well as a ventilation issue. If levels remain high without an obvious indoor activity, repeat the test, check the monitor location and consider outdoor conditions or a combustion source.
Inputs and assumptions
Your estimate is only as reliable as the measurement process. Before making a decision about a whole-house ventilation system or air-quality service, check the following inputs:
- Monitor capability: confirm whether the device measures CO2 directly or estimates it from other inputs. For PM2.5, check whether the sensor is designed for particles and whether the display shows a concentration or an index.
- Sensor condition: follow the manufacturer’s instructions for battery care, cleaning, placement and calibration or verification. Do not compare two devices as though their readings are identical without checking their specifications.
- Room and occupancy: record floor level, approximate room size, number of occupants and whether doors are open. A small occupied bedroom and a large open-plan room will behave differently.
- Ventilation type: note extractor fans, trickle vents, PIV, MVHR or other systems. Record whether filters are clean, fans are running and air inlets are unobstructed.
- Moisture sources: include showers, baths, cooking, wet laundry, drying clothes indoors and any water ingress. Ventilation can remove moisture, but it cannot replace repairs or source control.
- Combustion sources: record gas hobs, solid-fuel appliances, boilers, fireplaces, incense and smoking. Carbon monoxide is different from CO2 and requires a suitable carbon-monoxide alarm; a standard indoor air-quality monitor should not be assumed to detect it.
Humidity readings are particularly sensitive to temperature and position. Compare like with like: use the same room, height and time of day where possible. If windows show condensation, also inspect cold corners, external walls and areas behind furniture rather than relying on the monitor alone.
Worked examples
Example 1: a damp bedroom
A monitor records moderate readings before bedtime, then humidity and CO2 rise overnight. The bedroom window is wet in the morning and the readings fall slowly after the occupants leave. First check whether background ventilation is open and working, whether furniture is tight against an external wall, and whether the room is being dried by short, controlled airing or suitable mechanical ventilation. If the pattern continues, a ventilation assessment can help determine whether an extractor, PIV system or another approach is appropriate. Read the condensation checklist for homes with new windows if the issue started after replacement glazing.
Example 2: PM2.5 peaks during cooking
PM2.5 rises sharply when frying and falls after the cooker hood is used with the kitchen door closed and a suitable air inlet available. The practical response is to use extraction at the start of cooking, keep it running afterwards according to the manufacturer’s guidance, use lids where appropriate and avoid unnecessary indoor particle sources. If the hood is noisy, weak or recirculates without effective filtration, consider a kitchen extractor fan replacement or assessment.
Example 3: high CO2 in a home office
CO2 rises steadily during a working day with the door closed, while humidity remains stable. This points more strongly to an air-change problem than a moisture problem. Test whether opening a window or using an existing ventilation system changes the reading, while considering noise, security, outdoor pollution and heat loss. If the result is repeatable, professional airflow testing may identify whether the room has a blocked inlet, poorly balanced system or inadequate ventilation rate.
When to recalculate or retest
Revisit your measurements whenever the conditions change. Repeat the test after installing or repairing an extractor fan, cleaning an MVHR filter, adjusting a PIV system, replacing windows, adding insulation, changing room use or altering how laundry is dried. Seasonal checks are valuable because a home may need different ventilation habits in winter and summer.
Recalculate your conclusions rather than relying on an old log if occupancy changes, a room becomes a bedroom or office, or condensation returns after apparently improving. Compare before-and-after readings using similar times and activities. The room-by-room airflow checklist can help you pair monitor results with basic ventilation observations.
Take action in this order: remove or reduce the source where possible; use local extraction during moisture-producing or smoky activities; keep air inlets and grilles clear; check filters and fan operation; then arrange professional advice if readings remain persistently poor. For system choices, the guide to MVHR, PIV and extractor fans explains why the best solution depends on the building, the problem and the available airflow paths. Keep your weekly log so you can test whether any change genuinely improves indoor air quality rather than relying on a single reassuring reading.